2221
STEP 2: SURFACE BURNERS
1. To replace the nozzles of the surface burners, lift up the burners and unscrew the
nozzles shipped with the range using a 7 mm (socket wrench).
2. Replace nozzles using the conversion set supplied with the range. Each nozzle
has a number indicating its flow diameter printed on the body. Consult the table
on page 16 for matching nozzles to burners.
INSTALLATION
NG = Natural Gas
LPG = Liquid Propane Gas
NG LPG
9/32
9/32
Step1
Step 2
Step 3
Step 4
Step 5
Gas Conversion Procedure
STEP 3: FLAME ADJUSTMENT
1. Light one burner at a time and set it to the MINIMUM position (small flame).
2. Remove the knob.
3. The range is equipped with a safety valve. Using a small-size flathead
screwdriver, locate the choke screw (see diagram below) and turn to the right or
left until the burner flame is adjusted to desired minimum.
4. Make sure that the flame does not go out when switching quickly from the
MAXIMUM to the MINIMUM position.
The high flame setting cannot be adjusted to be lower. If the height is too high, revisit
the conversion set up. A step may have been missed.