CONNECTING THE POWER
Step 4 3-wire power cord
WARNING
Electrical Shock Hazard
Electrical ground is required on this appliance.
Do not connect to the electrical supply until appliance is permanently grounded.Disconnect power to the
circuit breaker or fuse box before making the electricalconnection.
This appliance must be connected to a grounded,metallic,permanent wiring system,or a grounding
connector should be connected to the grounding terminal or wire lead on the appliance.Failure to do any
of the above could result in afire,personal injury or electrical shock.See below for more information on
electrical grounding.
A. Remove the 4 lower terminal screws from the terminal block.
B. Insert the Green ground terminals together with white one.
C. Insert the 3 terminal screws through each power cord terminal and into the lower terminals of the
terminal block.Be certain that match the wire and terminals by color.
D. Tighten screws securely into the terminal block.
CAUTION
You must check voltage after connecting power cord.
Live 1-Neutral 120 V
Live 2-Neutral 120 V
Step 5.Replacing the terminal block cover
Replace the terminal block cover on the range back and tighten the screw.