TEC_TM_155 | REV. D | EN09/23/2022Page 6 of 66
P#829867
INSTALLATION CHECKLIST
To ensure no part of the installation process has been overlooked, complete the checklist below.
☐ Has an authorized True dealer or licensed installer inspected stainless steel surfaces
for imperfection?
(Cosmetic defects are covered by a limited 30-day warranty)
☐ Have all packaging materials been removed?
☐ Is the unit properly leveled with all leveling legs contacting the floor?
☐ Has the water filter been installed? Has the water supply been turned on?
☐ Have the water supply and drain connections been made?
☐ Is the water supply temperature always between 40-100˚F (4.4-7.8˚C)?
☐ Has the ice machine drain line been routed into an open drain with no more than 48”
(1,219.2 mm) vertical rise for 1/2” I.D. tubing and no more than 100’ (30.48 m) run?
☐ Has the water supply been turned on?
☐ Is the power cord plugged into a properly grounded three-prong outlet in accordance with all
applicable electrical codes?
☐ Have all connections been checked for water leaks? If not, pour water directly into the ice storage
bin to ensure drain pump operation and inspect for leaks.
☐ Were the ice maker and storage bin disinfected prior to use? If not, see “Sanitizing” (page 52).
☐ Has the ice machine been turned on? During the initial fill, can you hear the water valve turn on and
see water filling the reservoir tank?
☐ After the first ice cycle, did all 24 ice cubes fall into the bin during harvest?
☐ Have the first two batches of ice been discarded?
☐ Has the customer reviewed the unit’s operation in this manual?
☐ Has the customer reviewed the schedule of maintenance of the machine?