Axis A4011-E Reader

Installation Guide - Page 8

For A4011-E.

PDF File Manual, 12 pages, Read Online | Download pdf file

A4011-E photo
Loading ...
Loading ...
Loading ...
AXIS A4011-E Reader
Identication Types
Identication types are portable credential storage devices, pieces of memorized information, or
various combinations of the two that determine how users will be granted access to the door.
Common identication types include tokens such as cards or key fobs, personal identication
numbers (PINs), and request to exit (REX) devices.
The reader supports the following formats:
MIFAREp DESFirep
MIFAREp Classic
iClassp
To program the reader for MIFAREpClassic sector reading, a customer-specic setup card is needed.
For more information, contact Axis Support at www.axis.com/techsup.
Power & Data Connector
4-pin terminal block for DC power input and data. Supports RS485 and
OSDP protocols for communication with the door controller.
NONO
NO
TICETICE
TICE
Use a Safety Extra Low Voltage (SELV) compliant limited power source (LPS) with either
a rated output power limited to100 W or a rated output current limited to 5 A. For
example, AXIS A1001 Network Door Controller fullls these requirements when powered
by Power over Ethernet (PoE) or a SELV-compliant LPS.
Function Pin Notes
Specications
DC input
1
Power input from controller or
external power supply. Note: This
pin can only be used as power in.
Min 12 V DC (-10%)
Max 24 V DC (+15%)
0VDC(-)
2
3
A
RS485
4
For half duplex RS485 (RX/TX)
B
Important
The recommended maximum cable length is 30 m (98.4 ft).
To use the reader with AXIS A1001, connect the RS485 wires from A to B and from B to A.
For more information about Axis network door controller connections, see the hardware
pin chart, generated through the door controller’s hardware conguration, and the User
Manual, available at www.axis.com.