9
Notification Command Class, V8
Sensor Condition Command Class and Value Association Group
AC mains power
reconnected
Notification Report
Type: 0x08 Power Management
State: 0x03 AC mains reconnected
1 (Lifeline)
AC mains power
disconnected
Notification Report
Type: 0x08 Power Management
State: 0x02 AC mains disconnected
1 (Lifeline)
Watchdog Notification
Notification Report
Type: System 0x09
State Value: 0x04 System Software Failure
State Parameter Value = 0x55
1 (Lifeline)
Software Fault (Ring)
Notification Report
Type: System 0x09
State Value: 0x04 System Software Failure
State Parameter Value = 0xAA (Ring Value for Soft Fault)
1 (Lifeline)
Software Fault (SDK)
Notification Report
Type: System 0x09
State Value: 0x04 System Software Failure
State Parameter Value = 0xA9 (SDK Value for Soft Fault)
1 (Lifeline)
Software Reset
(Not triggered by failure)
Notification Report
Type: System 0x09
State Value: 0x04 System Software Failure
State Parameter Value = 0xAC
1 (Lifeline)
Power On Reset
Notification Report
Type: 0x08 Power Management
Event Parameter: 0x01 Power has been applied
1 (Lifeline)
Brownout
Notification Report
Type: 0x08 Power Management
Event: 0x05 Voltage Drop/Drift
1 (Lifeline)
Pin Reset (soft reset)
Notification Report
Type: System 0x09
State Value: 0x04 System Software Failure
State Parameter Value = 0xAB
1 (Lifeline)
Dropped Frame
Notification Report
Type: System 0x09
State Value: 0x04 System Software Failure
State Parameter Value = 0xAD
1 (Lifeline)