Installation
www.bora.com
No sealing tape is required on the side of the appliance
adjacent to the extraction system as the extraction
frame can otherwise be damaged.
With surface mounting, attach the enclosed sealing
tape [2] to the underside of the device before installing
it. Do not leave any gaps with the exception of the side
adjacent to the extraction system.
With flush installation, attach the enclosed sealing tape to
the horizontal cutting edge in the worktop cut-out, even if
you seal the device with a silicone sealant [1] or similar.
Note down the type designation and build number of
the device (FD number) on the back of this manual.
Both details can be found on the nameplate on the
underside of the device.
5.5 Installing the cooktop
INFO Clearance of one millimetre should be planned
between the built-in appliances.
INFO A clearance of two millimetres should be
planned around the built-in appliances.
Installing the cooktop
12
Fig. 5.9 Installed cooktop with cooktop extractor
[1] Cooktop
[2] Cooktop extractor
Insert the cooktop [1] next to the cooktop extractor [2]
that has already been installed in the centre.
INFO The cooktop [1] lies on the side rail of the
cooktop extractor [2], which stabilises it.
Precisely position the cooktop [1].
If necessary, use the height adjustment plates to
adjust the cooktop’s installation height.
10
10 – 40
Fig. 5.6 Surface mounting cut-out
Cut-out dimensions when installing cooktops or cooktops
and the BORA cooktop extractor next to each other:
Cooktops/cooktop extractor B in mm
1/0 320
2/0 661
3/0 1002
2/1 752
3/2 1184
4/2 1525
Tab. 5.3 Cut-out dimensions
Attaching the sealing tape
1
2
Fig. 5.7 Sealing tape with ush installation
[1] Black, heat-resistant silicone sealant
[2] Sealing tape
2
1
Fig. 5.8 Sealing tape with surface mounting
[1] Black, heat-resistant silicone sealant
[2] Sealing tape