77
Then sequential queue trigger setting finished (refer to Fig.5-61) and data ready for
acquisition.
Fig.5-61Sequential queue trigger
5. Distributed queue trigger: make BUS as trigger source and dis-continuous setting data
in BUS as trigger condition to generate trigger and also can set 8 data at the same time.
Distributed queue trigger menu refer as Fig.5-62
Fig.5-62Distributed queue trigger menu
Distributed queue trigger function as below:
Function
Setting
Instruction
Source
BUS0
BUS3
Select the trigger source from BUS0~BUS3
Code
0x0000
0xffff
HEX
0
65535
Can be set discretionarily between 0x0000 and 0xffff
HEXor between 0 and 65535 (DECaccording to
the bus and code setting.