Installation
STEP 1
Read the Safety Instructions
• It is very important to read the safety instructions on pages 4 and 5.
IMPORTANT: It is the installer’s responsibility to comply with installation clearances.
STEP 2
Unpack Range Hood and Prepare Tools
• Carefully unpack the range hood and parts. Make sure all parts are included as shown on page 6.
• DO NOT remove the protective lm covering the appliance until the installation is fully completed.
• Consult a qualied and trained installer or check local codes for makeup air requirement, if any.
STEP 3
Plan Desired Location
• Designed for ceiling heights between 8.8 ft. to 9.5 ft. (2.6 - 2.9 m) only. Refer to Height and Clearance section.
• Plan a desirable location that ts all requirements in the Safety and Installation sections of this manual. Plan where
and how the ductwork will be installed.
• A straight or short duct run will allow the unit to perform most efciently. Long duct runs, elbows and transitions
will reduce the performance of the unit. Each elbow is equivalent to 5 to 10 feet (1.5 m to 3 m) of straight run.
Propersizeductworkshouldbe6in.(15.3cm)indiameter.
• To reach a 9 foot ceiling make sure hood is installed 30 in. (76.2 cm) from cooking surface.
• If ductwork is already installed, ensure ductwork is free from debris and measures 6 in.
(15.3 cm).
• Installa120V60Hzelectricaloutletontheceilingwithinthedimensionsofthedecorativechimney.Note:Removalof
the plug will void the warranty of the range hood.
• Note that the bottom of the bracket must be level to ensure that the island range hood hangs level.
STEP 4
Test Unit Functions
• Plug the unit in and test all the functions before installing.
• Placetherangehoodonaat,stablesurface.Connecttherangehoodtoadesignatedstandardoutlet(120-Volt,60Hz,
AC only) and turn on the range hood. Verify all operations of the range hood by referring to
Range Hood Operations.
• Turn power On in control panel.
• Check all lights and fan operations.
WARNINGS:
• PleasemakesuretoreadALLsafetyinstructionsonpages4and5.
• Usetwoormorepeopletomoveandinstallrangehood.
• Failuretofollowtheseinstructionscanresultinseriousinjury.