Hoshizaki KM901MRJ KM-901MRJ 30" Energy Star Ice Modular with 950 lbs. Daily Ice Production, Remote Cooled, H-Guard Plus, Phase 1, and CycleSaver Design, in Stainless Steel

Instruction Manual - Page 6

For KM901MRJ.

PDF File Manual, 41 pages, Read Online | Download pdf file

KM901MRJ photo
Loading ...
Loading ...
Loading ...
6
I. Specications
A. Electrical and Refrigerant Data
The rating label and nameplate provide electrical and refrigerant data. The rating label
can be seen by removing the front panel. The nameplate is located on the rear panel. For
certication marks, see the nameplate.
We reserve the right to make changes in specications and design without prior notice.
1. KM-901M_J/3
Single Phase
Model Number KM-901MAJ KM-901MWJ KM-901MRJ
AC Supply Voltage 208-230/60/1 208-230/60/1 208-230/60/1
Compressor 208-230V 9.3RLA 46LRA 208-230V 7.7RLA 46LRA 208-230V 7.7RLA 46LRA
Pump 120V 1.2FLA 60W 120V 1.2FLA 60W 120V 1.2FLA 60W
Fan 115V 1.0A 1/15HP (EACH) --- --- --- 120V 3A MAX (Fan in URC)
Other 115-120V 0.3A 115-120V 0.3A 115-120V 0.3A
Maximum Fuse Size 20 AMPS 20 AMPS 20 AMPS
Max. HACR Breaker
(USA Only)
20 AMPS 20 AMPS 20 AMPS
Max. Circuit Breaker
(Canada Only)
20 AMPS 20 AMPS 20 AMPS
Minimum Circuit
Ampacity
20 AMPS 20 AMPS 20 AMPS
Design Pressure HI-467PSI LO-230PSI HI-427PSI LO-230PSI HI-467PSI LO-230PSI
Refrigerant 404A 3 LB. 4.9 OZ. 404A 1 LB. 14 OZ. 404A
Total Refrigerant Charge with
Hoshizaki Remote Condenser
Unit URC-14F: 12 LB. 5.5 OZ.
Three Phase
Model Number KM-901MRJ3
AC Supply Voltage 208-230/60/3
Compressor 208-230V 5.5RLA 36LRA
Pump 120V 1.2FLA 60W
Fan 120V 3A MAX (Fan in URC)
Other 115-120V 0.3A
Maximum Fuse Size 20 AMPS
Max. HACR Breaker
(USA Only)
20 AMPS
Max. Circuit Breaker
(Canada Only)
20 AMPS
Minimum Circuit
Ampacity
20 AMPS
Design Pressure HI-467PSI LO-230PSI
Refrigerant 404A
Total Refrigerant Charge with
Hoshizaki Remote Condenser
Unit URC-14F: 12 LB. 5.5 OZ.
Loading ...
Loading ...
Loading ...