1. Icemaker
Icemaker Water
Supply Inlet
Minimum Icemaker
Water Supply Line Size
Icemaker Drain
Outlet
Minimum Icemaker
Drain Line Size
Condensation
Drain Outlet
1/2" Female Pipe
Thread (FPT)
3/8" Nominal ID
Copper Water Tubing or
Equivalent
3/4" Female Pipe
Thread (FPT)
3/4" Nominal
ID Hard Pipe or
Equivalent
3/8" OD Hard
Tube
An icemaker water supply line shut-off valve and drain valve must be installed.
• Be sure there is sufficient extra water supply line and drain line for the appliance to be
pulled out for service.
Fig. 5
Model Shown:
KM-1601MRJ
Air-Cooled and Remote Models
Remote Condenser
Line Set Connections
Shut-Off Valve
Drain Valve
Icemaker
Icemaker Water Supply Inlet
1/2" FPT
Bin Drain Outlet
3/4" FPT
2-inch (5-cm) air gap
Floor
Drain
Icemaker
Drain Outlet
3/4" FPT
Minimum 3/8" Nominal ID Copper
Water Tubing or Equivalent
Icemaker
Condensation
Drain Outlet
3/8" OD Hard
Tube
Vent Tube
Minimum 3/4" Nominal ID
Hard Pipe or Equivalent
Ice
Storage
Bin
Separate piping to approved
drain. Leave a 2-inch (5-cm)
vertical air gap between the
end of each pipe and the
drain.
Be sure there is sufficient
extra water supply line and
drain line for the appliance
to be pulled out for service.