Description of the oven
8
Installation
Neutral
(N)
Phase
(L)
bleu
green yellow
Black,brown or
red
Warning
The safety wire (green-yellow) is connected
to the appliance’s terminal and must be
connected to the earth terminal of the elec-
trical set-up.
The fuse in your set-up must be 16 amperes.
ELECTRICAL CONNECTION
Your oven must be connected with a (standard)
power cable with 3 conductors of 1.5mm
2
(1 live
+ 1 neutral + earth) which must be connected to
a 220-240V
~
single-phase grid by means of a 1
live + 1 neutral + earth CEI 60083 standard power
-
ance with the installation rules.
We cannot be held responsible for any accident resulting
with the door closed for about 15 minutes on the
highest temperature. to break in the appliance.
The mineral wool surrounding the oven cavity may
-
position. You may also notice smoke development.
This is normal.