Standard Extender/Splitter Installation
1
Make sure the DVI source is powered OFF.
2
Connect the DVI source to the DVI port on the B140-002 or
B140-004 labeled INPUT using a Tripp Lite P561-Series DVI-D Single-
Link Cable.
3
Optional for B140-004: Connect a DVI monitor to the DVI port on the
B140-004 marked LOCAL using a Tripp Lite P561-Series DVI-D Single-
Link Cable.
4
Connect the external power supply to the B140-002 or B140-004
local unit and plug it into a Tripp Lite Surge Protector, PDU or UPS. The
green RJ45 LEDs and red Power LED on the B140-004 will illuminate
to indicate power is being received from the external power supply. The
green RJ45 LEDs on the B140-002 will illuminate to indicate power is
being received from the external power supply.
5
Using Cat5e/6 cable, connect one of the RJ45 output ports on the local
unit to the RJ45 input port on the B140-1P0, B140-1A0 or
B140-1A0-WP-1 remote unit.
6
Repeat step 5 for each additional remote unit you are connecting.
7
B140-1A0 and B140-1A0-WP-1 only: Connect the external power
supply to the B140-1A0 or B140-1A0-WP-1 and plug it into a Tripp Lite
Surge Protector, PDU or UPS. The green RJ45 LED on the B140-1A0
and the green LED on the B140-1A0-WP-1 will illuminate to indicate
that the unit is receiving power.
8
Repeat step 7 for each additional B140-1A0 or B140-1A0-WP-1 in the
installation.