36” GAS RANGETOP INSTALLATION INSTRUCTIONS
Testing for gas leaks
Gas leak tests should be performed before the test-
ing the electric ignition of the burners:
1. Turn on gas supply.
2. Apply a non-corrosive leak detection fluid (e.g.
soapy water) to all joints and conduits.
3. If bubbles appear, it means there is a leak. Turn
off the gas supply and tighten the connections.
4. Retest for leaks. If no bubbles appear, the test is
passed. Wipe off all residues of detection fluid.
Testing the electric ignition of the
burner
This test should be performed after the range and
supply line connectors have been carefully checked
for leaks and the range connected to the electric
power supply:
1. Push in and turn a surface burner knob to the low
flame position. You will hear the igniter sparking.
2. The surface burner should light when gas is sup-
plied to the cooktop burners. Each burner should
light within four (4) seconds, after air has been
purged from supply lines. Visually check that
burner has lit.
3. Once the burner lights, the control knob should
be rotated out of the low flame position.
4. There are separate ignition devices for each
burner. Try each knob separately and together
until all burner valves have been checked.
Adjusting the minimum gas setting
Since all cooktop burners are of the dual-flame type,
the minimum gas setting must be adjusted for both
the outer and inner rings.
These instructions refer to a single burner. Repeat
the following for each cooktop burner.
1. Push in the burner control knob and light it at the
minimum position
.
2. Remove the burner control knob, along with the
conical spring and knob ring.
3. Tighten or loosen the highlighted screws to adjust
the minimum flame height.
Conversion to Propane gas (LPG)
Always provide an adequate gas supply.
This appliance is shipped from the factory for use
with natural gas. Use this kit to convert the appli-
ance for use with propane gas, if necessary. Comply
with the following: Ensure that the range is con-
verted for use with the appropriate gas before using
it. This appliance is designed to operate at a pres-
sure of 10" of water column when used with propane
gas.
WARNING NEVER use a flame to check for
gas leaks.
WARNING
• Before proceeding with the gas conversion, the
gas supply must be turned off before disconnect-
ing the electrical power.
• A gas leak test should be performed after the gas
conversion has been carried out.