100592 - 6250W DUAL FUEL GENERATOR
V
TROUBLESHOOTING
30
TROUBLESHOOTING
Problem Cause Solution
Engine will not start.
No fuel. Add fuel.
Faulty spark plug. Clean and adjust spark plug or replace.
Low oil level.
Fill crankcase to the proper level.
Place generator on a flat, level surface.
Spark plug wire loose. Attach wire to spark plug.
Fuel valve is closed. Open fuel valve.
Engine switch OFF. Press Engine ON.
Old fuel or water in fuel. Drain fuel and replace with fresh fuel.
Flooded with fuel. Let unit stand for 10 mins.
CO Shield
®
module has been removed or
tampered with.
Re-install module or contact technical support.
Engine starts but runs roughly.
Choke in the wrong position.
Move choke until it stops under RUN position or
push in completely.
Dirty air filter. Clean or replace air filter.
Dirty fuel valve. Clean the fuel valve.
Clogged spark arrestor. Clean spark arrestor.
Engine shuts down during operation.
Out of fuel. Fill fuel tank.
Low oil level.
Fill crankcase to the proper level. Place generator
on a flat, level surface.
If equipped, when CO Shield
®
shutoffs
occur due to accumulating carbon
monoxide (CO) and if the red LED light
blinks on the panel.
Move generator to an open, outdoor area. Point
exhaust away from people and buildings. Move
to fresh air and get medical help if sick, dizzy, or
weak.
Make sure there are no objects creating
obstructions within 5 feet of the generator.
Obstructions in the vicinity of the generator
may trap carbon monoxide emissions near the
generator and cause the engine to shutoff.
If the generator’s exhaust is facing into the
wind, the exhaust may be blown back into
the generator’s operating area, creating an
accumulation of CO emissions and triggering an
engine shutoff. To avoid an engine shutoff, turn
the generator 45° in either direction to allow
the exhaust emissions to blow away from the
generator. If engine shutoff events continue,
readjust and align the exhaust with the wind
direction to blow away from the generator.
If equipped, when CO Shield
®
shutoffs
occur due to system fault and if the
yellow LED light blinks on the panel.
Start by confirming yellow LED light blinks when/
if generator shuts off. If CO Shield
®
continues to
sense the fault and shuts off, contact technical
support.
Clogged spark arrestor. Clean spark arrestor.