100592 - 6250W DUAL FUEL GENERATOR
V
ASSEMBLY
15
ASSEMBLY
Your generator requires some assembly. This unit ships from our
factory without oil. It must be properly serviced with fuel and oil
before operation.
If you have any questions regarding the assembly of your
generator, call our Technical Support Team at 1-877-338-0999.
Please have your serial number and model number available.
Unpacking
1. Set the shipping carton on a solid, flat surface.
2. Remove everything from the carton except the generator.
3. Carefully cut each corner of the box from top to bottom. Fold
each side flat on the ground to provide a surface area to work
with the generator.
Install the Wheel Kit
CAUTION
The wheel kit is not intended for over-the-road use.
Install the Wheels
1. Before adding fuel and oil, tip the generator onto it’s recoil
end.
2. Remove wheel hub cap (B) from wheel by inserting a small
screwdriver into the slot provided and pry upward.
3. Slide the roll pin (C) through the wheel (A) from the outside.
4. Slide the roll pin through the mount point on the frame.
5. Insert r-clip (D) into hole at end of roll pin.
6. Re-install hub cap on wheel.
7. Repeat to attach the second wheel.
Install the Support Leg
1. Attach the support leg (E) to the generator frame with flange
bolts (F) and flange lock nuts (G).
2. Slowly tip the generator back down so that it rests on the
wheels and support Leg.
Add Engine Oil
CAUTION
DO NOT attempt to crank or start the engine before it has been
properly filled with the recommended type and amount of oil.
Damage to the generator as a result of failing to follow these
instructions will void your warranty.
NOTICE
The generator rotor has a sealed, pre-lubricated ball bearing
that requires no additional lubrication for the life of the bearing.
NOTICE
The recommended oil type for typical use is 10W-30
automotive oil.
If running generator in extreme temperatures, refer to the
following chart for recommended oil type.
-20 0 20 40 60
Ambient temperature
Recommended Engine Oil Type
80 100 120
-28.9
°F
°C -17.8 -6.7 4.4 15.6 26.7 37.8 48.9
10W-30
5W-30 Full Synthetic
10W-405W-30
1. Place the generator on a flat, level surface.
2. Remove oil fill cap/dipstick to add oil.
D