100592 - 6250W DUAL FUEL GENERATOR
V
OPERATION
18
WARNING
If there is a strong smell of LPG: Close valve on the cylinder.
Check all connections for leaks by wetting the fittings with a
solution of soap and water. Bubbles which appear or bubbles
which grow indicate that a leak exists. Do not smoke or light a
cigarette, or check for leaks using a match, open flame source
or lighter. Contact a qualified technician to inspect and repair
an LPG system if a leak is found, before using the generator.
Grounding
Your generator must be properly connected to an appropriate
ground to help prevent electric shock.
WARNING
Failure to properly ground the generator can result in electric
shock.
A ground terminal connected to the frame of the generator has
been provided (see Controls and Features for terminal location).
For remote grounding, connect of a length of heavy gauge
(12 AWG minimum) copper wire between the generator ground
terminal and a copper rod driven into the ground. We strongly
recommend that you consult with a qualified electrician to ensure
compliance with local electrical codes.
Neutral Floating*
Neutral circuit IS NOT electrically connected to the frame/
ground of the generator.
The generator (stator winding) is isolated from the frame and
from the AC receptacle ground pin.
Electrical devices that require a grounded receptacle pin
connection will not function if the receptacle ground pin is not
functional.
Neutral Bonded to Frame*
Neutral circuit IS electrically connected to the frame/ground of
the generator.
The generator system ground connects lower frame cross-
member below the alternator. The system ground is connected
to the AC neutral wire.
* See your Specifications section for specified type of grounding.
OPERATION
CO Shield
®
- Carbon Monoxide (CO) Detection
and Auto-shutoff System
The CO Shield
®
technology monitors the accumulation of
poisonous CO gas produced by engine exhaust when the generator
is running. If CO Shield detects elevated levels of CO gas, it
automatically shuts off the engine. Generators are intended to
be used outdoors, far away from occupied buildings and exhaust
pointed away from people and buildings.
If misused and operated in a location that results in the
accumulation of CO inside an enclosed or partially enclosed space,
for example a house, garage or a garage with the door partially
open, CO Shield will automatically shut off the generator and then
illuminate a red LED. Read the action label for what steps to take.
CO Shield is not a substitute for an indoor carbon monoxide
alarm.
1607-L-SF-C
AUTOMATIC SHUTOFF – YOU MUST:
APAGADO AUTOMÁTICOUSTED DEBE:
ARRÊT AUTOMATIQUE– VOUS DEVEZ :
Move generator to an open, outdoor area. Point exhaust away. Don’t run generators
in enclosed areas (e.g. not in house or garage).
Mover el generador a un área abierta a la intemperie. Apunte el escape alejado. No corra los
generadores en áreas cerradas (ej. no en una casa o garaje).
Déplacer le générateur vers un espace extérieur
en plein air. Garder l’échappement loin. Ne pas
faire fonctionner les générateurs dans un espace
clos (ex., pas dans une maison ou un garage).
ACTION LABEL
ETIQUETA DE ACCIÓN
ÉTIQUETTE D'ACTION
EXHAUST
EL ESCAPE
L’ECHAPPEMENT
POINT AWAY
DIRIJA ALEJADO
DIRIGER LOIN
Move to fresh air and get medical
help if sick, dizzy or weak.
Mueva al aire fresco y obtenga
asistencia medica si es
enfermo, mareado, o débil.
Aller à l'air frais et obtenir de
l'aide médicale si malade,
étourdi ou faible.
PROCESS
ColorsLPN 1 607-L- SF
Rev C
Size ~276 .4 x 82.3 mm
Artwork Notes
2mm safe margin;
to be prin ted on white su bstrate
Revision Changes
B: Updated dieline
C: Delet ed “25 ft./ 7 m
This art work belongs to Champi on Power Equipment. Th e contents are con dential and privile ged and shall not be disclo sed to or used by or for
outside par ties without th e explicit consent o f Champion Power Equi pment.
K
485 152 109
When you approach the generator to investigate a shut off, a
blinking red LED light in the CO Shield area provides notification
that the generator shut off due to an accumulating CO hazard. The
red LED light will blink for at least five (5) minutes after a shutoff
event.
AUTOMATIC SHUTOFF
SEE ACTION LABEL
APAGADO AUTOMÁTICO
VEA ETIQUETA DE ACCIÓN
AUTOMATIC SHUTOFF
SEE ACTION LABEL
APAGADO AUTOMÁTICO
VEA ETIQUETA DE ACCIÓN
SERVICE
REALICE UN SERVICIO
SERVICE
REALICE UN SERVICIO