Karcher 1.574-004.0 IB 7/40 Advanced, Surpass Industrial 3363N, Clear display, Automatic residual ice emptying

Operating instructions - Page 11

For 1.574-004.0. Also, The document are for others Karcher models: IB 7/40 CLASSIC, IB 7/40 ADVANCED

PDF File Manual, 40 pages, Read Online | Download pdf file

1.574-004.0 photo
Loading ...
Loading ...
Loading ...
English 11
Faults without display on the console
Fault Possible cause Remedy By whom
No display in-
spite of power
switch in posi-
tion 1
Mains Plug not connected to the socket. Insert the mains plug into a socket. Operator
Fuse F1 blown Remove side panel, press F1 to reset. Operator
No com-
pressed air jet
despite the
trigger being
drawn
Compressed air supply has too little pressure Check pressure level. Operator
Jet pressure is set too low Set the jet pressure to a higher level. Operator
Power supply has been interrupted Check power supply. Indicator lamp "De-
vice on" must glow green.
Operator
Emergency-stop button has been pressed. Release emergency-stop button by turn-
ing. Indicator lamp "Device on" must glow
green.
Operator
Control cable not connected properly Check connection between control cable
and the jet pistol and between the control
cable and the device.
Operator
Control cable is defective Replace spray agent hose. Operator
Compressed
air jet is too
weak
Jet pressure is set too low Set the jet pressure to a higher level. Operator
Compressed air supply has too little pressure
or the compressor output is low.
Check pressure and output. Operator
The filter insert in the water separator is
plugged.
Replace the filter inlay in the water separa-
tor.
Operator
Spray agent hose or jet pistol is blocked Let the spray agent hose and jet pistol
come to room temperature and remove
the blocking. Increase working pressure
and / or reduce the dry ice dosing.
Operator
No dry ice pel-
lets in the com-
pressed air jet
Dry ice dosing switched off (IB 7/
40 Advanced only), button "Dry ice dosing
on/off" on the jet gun lights glows red, display
shows "Ice off".
Press the dry ice dosing key on the jet pis-
tol.
Operator
Dry ice container is empty Refill the dry ice container Operator
Dry ice has melted Empty the dry ice container and refill it with
fresh dry ice pellets.
Operator
Vibrator on the dry ice container is not work-
ing
Call Customer Service. Operator
Drive motor of the dosing equipment is over-
loaded
Let the dosing thaw Operator
Compressed air is exiting into the dry ice
container
Clean the pressure balance channel in the
dosing equipment.
Customer
Service
Dosing disc in the dosing unit is defective Replace the dosing disc. Customer
Service
Loading ...
Loading ...
Loading ...