Bosch HSH23505ME/02 FREE-STANDING GAS COOKER

User Manual - Page 33

For HSH23505ME/02.

PDF File Manual, 36 pages, Read Online | Download pdf file

HSH23505ME/02 photo
Loading ...
Loading ...
Loading ...
33
4. To reassemble, follow the instructions in the reverse order
and pay attention to the 4 screws in the back wall of the
cooking compartment when inserting the removable floor.
Grill burner
Replacing the nozzles
1. Undo the screw on the left and the 2 screws on the right of
the grill burner and pull the burner downwards and towards
the front slightly.
2. Unscrew the nozzle and replace it with a nozzle which is
suitable for the new type of gas (see "General nozzle table"
section).
3. Replace the gas label with the new label that was supplied
with the nozzle set.
4. To reassemble, follow the instructions in the reverse order.
Setting the minimum gas flow
This setting option is not available on model HSG722054M.
1. Open the appliance door.
2. Press the control knob for the oven and turn it anti-clockwise
to the maximum setting of 250. The gas burner ignites. Hold
the control knob depressed for around 15 seconds and then
release it.
3. Close the appliance door.
4. Remove the control knob.
5. Through the gas tap opening in the control panel, loosen the
internal setting screw.
6. Replace the control knob and heat the oven for 15 minutes.
7. Then turn the control knob to the minimum setting 140.
8. Remove the control knob again.
9. Now, through the gas tap opening in the control panel, adjust
the internal setting screw until a stable flame is burning
correctly.
Loosen the setting screw to increase the gas flow or tighten it
to decrease the gas flow. The setting is correct when the
height of the small flame is approx. 3 to 4 mm.
In the case of a connection to liquefied gas, tighten the
setting screw.
10.Refit the control knob.
11.Make sure that the flame does not go out when the gas flow
is changed quickly from maximum to minimum and vice
versa, and when the appliance door is opened and closed.
Regulating the primary air
The primary air is correctly set when the flame is stable and
blue/green.
1. Undo the screw.
2. Push the inner cover forwards or backwards.
The correct cover position can be determined from the
following table:
3. Tighten the screw again.
Type of gas Setting
G20/20 mbar
G30/29 mbar
Loading ...
Loading ...
Loading ...