Loading ...
Loading ...
Loading ...
LP Gas Model only:
Connect Regulator with Hose to your LP Gas Tank
[] Turn all Burner Valves to the OFF position.
[] Inspect the valve connection port and regulator
assembly for damage or debris. Remove any
debris. Never use damaged or plugged equip-
ment.
[] Connect the regulator assembly to the tank valve
and HAND TIGHTEN nut clockwise to a full stop.
DO NOT use a wrench to tighten because it could
damage the Quick Coupling Nut and result in a
hazardous condition.
[] Open the tank valve 1/4 to 1/2 of a turn (coun-
terclockwise) and use a soapy water solution to
check all connections for leaks before attempting
to light your grill. See "Checking for LP Gas
Leaks". If a leak is found, turn the tank valve off
and do not use your grill until the leak is repaired.
Type 1 connection per
ANSI Z21.58-2005/CGA
6b-2005 Quick
Coupling Nut
CAUTION: When the appliance is not in use the gas
must be turned off at the tank.
Check all connections for LP Gas Leaks
Never test for leaks with a flame. Prior to first use,
at the beginning of each season, or every time
your LP Gas tank is changed, you must check for
gas leaks. Follow these three steps:
[] Make a soap solution by mixing one part liquid
detergent and one part water.
[] Turn the grill Control Knobs to the full OFF
position, then turn the gas ON at source.
[] Apply the soap solution to all gas connections
indicated by the arrows. See diagram. If
bubbles appear in the soap solution the
connections are not properly sealed. Check
each fitting and tighten or repair as necessary.
Gas Valve / Manifold Assembly
Side Burner
Gas Vatve
Regulator with Hose (LPG)
LP Gas Tank
If you have a gas leak that cannot be repaired
by tightening, turn off the gas at the source,
disconnect fuel line from your grill and call
1-8O0-4-MY-HOME ® or your gas supplier for
repair assistance.
Disconnecting A Liquid Propane Gas (LPG)
Tank From Your Grill
[] Make sure the Burner Valves and LP Gas tank
valve are off. (Turn clockwise to close.)
[] Detach the hose and regulator assembly from
the LP Gas tank valve by turning the Quick
Coupling Nut counterclockwise.
17
Loading ...
Loading ...