Kenmore 14816136110 Official Gas Grill

User Manual - Page 31

For 14816136110.

PDF File Manual, 32 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Problem Possible Cause Corrective Action
Low heat,
LP gas
Sudden drop in
gas flow or low
flame
Cooking light will
not turn on.
LED control panel
lights do not light
up.
The propane regulator
assembly incorporates an
excess flow device designed
to supply the grill with
sufficient gas flow. Rapid
changes in pressure can
trigger the excess flow device,
providing a low flame
and low temperature.
1. Out of gas. 1.
2. Excess flow valve tripped. 2.
3. Vapor lock at coupling 3.
nut/LP cylinder connection.
1. No power supply. 1.
2. Defective halogen bulb.
3. Internal wiring issue.
2.
3.
1. No power supply. 1.
2. Damaged wiring or loose
connection. 2.
3. Wiring not attached to
control panel switch.
4. Defective switch.
5. Defective LED's.
Please follow these instructions:
1. Make sure all burners are "OFF".
2. Open the tank valve and wait 5
minutes.
3. Light the burner one at a time
following the lighting instructions
listed on the door liner
,
,
5.
Check for gas in LP cylinder.
Turn off knobs, wait 30 seconds
and light grill. If flames are still
low, turn off knobs and LP
cylinder valve. Disconnect
regulator. Reconnect regulator
and leak test. Turn on LP cylinder
valve, wait 30 seconds and then
light grill.
Turn off knobs and LP cylinder
valve. Disconnect coupling nut
from cylinder. Reconnect and
retry.
Check power supply and make
sure transformer is properly
plugged in.
Replace the bulb.
Check the wiring connections
under the fire box. All wire
connections must be tight. If any
wires are damaged they should be
replaced.
Install AA batteries in the LED
battery box.
Check all wiring connections
between the battery box and the
LED light. Also check the
connections between the LED's on
the control panel.
Check the connection between the
LED light and the LED light switch.
Replace the switch.
Replace the LED lights.
31