16 110CT425A/W, 110FB425A/W
Service
Lever models
The dispense wheelmotor is energized through the power and ice dispense switches. The water solenoid valve is
energized through the power and water dispense switches. The ice machine is controlled through an unpowered
contact closure bin thermostat circuit. When ice builds up around the bin thermostat, the contacts open, cutting the
bin signal to the ice machine.
SensorSAFE models
SensorSAFE models provide “touchless” ice and water dispensing. When a container is placed within the actuation
zone below the ice or water chute on SensorSAFE dispenser models, an infrared signal reects off the container
and is detected by the sensor. The sensor then sends a signal to the control board to activate the appropriate
components to dispense ice or water. LEDs on the board indicate when the board is receiving a signal from the
sensors.
A safety, shut-off feature automatically shuts off dispensing after one minute of continuous activation. Dispensing
can be restarted by moving the container away and then returning it to the actuation zone.
Dispensing can be temporarily suspended for cleaning by depressing and releasing the clean switch, located
under the left side of the top front cover. Depressing and releasing the button a second time will return the
dispenser to normal operating state. If the clean switch is not depressed a second time, the dispenser will
automatically resume normal dispense operation (CLN LED goes out) after two minutes. An LED on the control
board will light to indicate that the dispensing has been suspended by activation of the clean switch.