Installation Instructions
STACKING THE WASHER AND DRYER (if desired)
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT- Savetheseinstructions
for local electrical inspector's use.
IMPORTANT-Observeall governing
codes and ordinances.
Note to Installer- Be sure to leave these
instructions with the Consumer.
Note to Consumer - Keep these instructions
for future reference.
Service must be performed bg a qualified
installer.
Proper installation is the responsibility of
the installer.
FOR YOUR SAFETY:
-A WARNING -
Electric Shock Hazard. Disconnect power before
installing. Failure to do so could result in serious
injurg or death.
Potential Personal Injury. More than two people
are recommended to lift the dryer into position
because of its weight and size. Failure to do so
could result in personal injury or death.
Avoid Tipping and Rupture of Utilitg Services.
Drger must be securelg attached to the washer.
DO NOT place the washer on top of the drger.
Failure to do so could result in personal
injurg/death or propertg damage.
Mobile Home or Manufactured Home
Installation - Stacking of a gas drger is not
permitted in a mobile home or manufactured
home.
MINIMUM CLEARANCE OTHER THAN
ALCOVE OR CLOSET INSTALLATION
Minimum clearance to combustible surfaces
and for air opening are: 0" both sides, 1" front
and B" rear. Consideration must be given to provide
adequate clearance for installation and service.
REQUIREMENTS FOR ALCOVE OR
CLOSET INSTALLATION
Your drger is approved for installation in
an alcove or closet, as stated on a label on
the drLler back.
The drger MUST be vented to the outdoors. See
the EXHAUSTING THE DRYERsection.
Minimum clearance between drLler cabinet and
adjacent walls or other surfaces is:
0" either side
B" frontand rear
Minimum vertical space from floor to overhead
shelves, cabinets, ceilings, etc., is 52".
Closet doors must be Iouvered or otherwise
ventilated and have at least 60 square inches
of open area equallg distributed. If the closet
contains both a washer and a drger, doors must
contain a minimum of 120 square inches of open
area equallg distributed.
The closet should be vented to the outdoors
to prevent gas pocketing in case of gas in the
supplg line.
No other fuel-burning appliance shall be
installed in the same closet with the drger
(gas models onlg).
NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT
THE REAR OF THE DRYER, MINIMUM CLEARANCE
FROM THE WALL IS 5.5 INCHES.