Installation Instructions
CONNECTING AN ELECTRIC DRYER (cont.)
CONNECTING DRYER USING 3-WIRE
CONNECTION
If required,by
localcode,
install external
ground(not
provided)to
grounded
metal, cold
water pipe,
or other
established
ground
determined
by a qualified
electrician.
GreenGround Ground Strain
Screw Strap Relief
Hot Wire Bracket
Screws
Cover
.Neutral Wire
(white) ]
3/4" UL
Recognized
Strain Relief
3 #10AWGminimumcopper
conductorsor 120/240V3OApower
supplycordkit markedfor usewith
dryersandprovidedwith closedloop
or spadeterminalswith upturnedends
(not supplied)
1. Turn off the circuit breaker(s)(30 amp) or remove
the dryer's circuit fuse at the electrical box.
2. Be sure the dryer cord is unplugged from the
wall receptacle.
3. Remove the power cord cover located at the
lower back.
4. Install 3/4-in. UL-recognized strain relief to power
cord entrg hole. Bring power cord through strain
relief.
5. Connect power cord as follows:
A. Connect the 2 hot lines to the outer screws
of the terminal block (marked L1 and L2).
B. Connect the neutral (white)line to the center
of the terminal block (marked N).
6. Be sure ground strap is connected to neutral
(center) terminal of block and to green ground
screw on cabinet rear. Tighten all terminal block
screws (3) completely.
7. Properly secure power cord to strain relief.
8. Reinstall the cover.
WARNING - NEVERLEAVETHE
COVER OFF OF THE TERMINAL BLOCK.