Loading ...
Loading ...
Loading ...
CHANGE WATER PANEL INDICATOR
The control keeps track of humidier operation time. The yellow
Change Water Panel light ashes after a preset amount of running
time has elapsed. This running time is preset by the installer based
on the humidier model and water hardness.
Refer to the ANNUAL MAINTENANCE section for instructions on
changing the Water Panel or call your HVAC contractor for service.
TEST/RESET
The Test/Reset feature allows the humidier operation to be checked
even if there is no call for humidity.
1. The HVAC system fan must be running for the humidier to
function. Make a heat or fan call at your thermostat.
2. Set the knob to Test/Reset. Make sure the water saddle valve is
open and that there is electricity to the humidier.
3. The humidier will only operate for 1 minute in test mode.
4. Reduce the humidier control setting to the recommended inside
RH, depending on the outside temperature. DO NOT LEAVE IN
TEST MODE AS HUMIDIFIER WILL NOT OPERATE AFTER 1 MINUTE HAS
ELAPSED.
ADDITIONAL INFORMATION
Your humidier is a precision system that will accurately maintain the
RH in your home. For every 2°F change in outdoor temperature, the
Digital Humidier Control will automatically adjust the indoor RH by 1%.
The Automatic Digital Humidier Control will accurately control the
humidity in your home to a maximum of 45% RH.
The RH values in TABLE 2 are targets based on outdoor temperature
and the Automatic Digital Humidier Control setting. The actual RH
may vary due to conditions in the home (cooking, showering, etc.).
TABLE 2: % RELATIVE HUMIDITY GUIDE
Outdoor Temperature (°F)
10°F 0°F 10°F 20°F 30°F 40°F
Dial Setting
1 10% 10% 10% 15% 20% 25%
Relative Humidity (%)
2 10% 10% 15% 20% 25% 30%
3 10% 15% 20% 25% 30% 35%
4 15% 20% 25% 30% 35% 40%
5 20% 25% 30% 35% 40% 45%
6 25% 30% 35% 40% 45% 45%
7 30% 35% 40% 45% 45% 45%
TABLE 1: OUTDOOR
TEMPERATURE/INDOOR
RELATIVE HUMIDITY
Outside
Temperature
Recommended
RH
+40°F 45%
+30°F 40%
+20°F 35%
+10°F 30%
0°F 25%
-10°F 20%
-20°F 15%
9
Loading ...
Loading ...
Loading ...