OPERATING INSTRUCTIONS
MODELS 400M, 500M, 600M & 700M
Your AprilAire Humidier is controlled by a Manual Humidier Control
(see FIGURE C). The Manual Humidier Control is installed either in
the cold air return duct or on an interior wall of the home. With the
Manual Humidier Control, it is important to anticipate a drop in
outdoor temperature and reduce the RH set point accordingly to
avoid excessive condensation, just as with the Digital Humidier
Control installed in Manual mode (see page 8).
To determine the indoor RH, slowly turn the knob clockwise and
counterclockwise and listen for 2 clicks. The indoor RH is within the
range of the 2 clicks.
CHECK THE HUMIDIFIER OPERATION
MANUAL HUMIDIFIER CONTROL
1. The HVAC system fan must be running for the humidier to
function. Make a heat or fan call at your thermostat.
2. Set the knob to the highest RH set point, make sure that the water
saddle valve is open and that there is electricity to the humidier.
3. Return control knob to the desired RH set point.
90-1237
FIGURE C: MANUAL HUMIDIFIER CONTROL
11