Loading ...
7
NOTE: ALL ELECTRICAL CONNECTIONS MUST ONLY BE CARRIED OUT BY AN AUTHORISED
PERSON.
Each appliance should be connected to an adequately protected power supply and isolation switch mounted
adjacent to, but not behind the appliance. This switch must be clearly marked and readily accessible in
case of fire.
1. Check that the electricity supply is correct as shown on the
Rating Plate attached to the lower front
hand side of the
front sill panel.
2. The supply terminal connections are located at the rear of the
the appliance. Refer to Electrical Connectionsin the
Specificationssection of the manual.
3. Open the door and remove the control panel to allow
connection access for the electrical supply.
4. Bring the supply cable up through the compression type gland
provided on the rear of the main electrical switchgear panel.
5. Connect the mains supply to L1, L2 and L3 connections for 3
phases. Refer to the 'Electrical Supply Requirements' section
for connection details.
6. Connect neutral and earth conductors to neutral stud and
earth stud respectively.
7. For all connections ensure that conductors are secure and
appropriately terminated.
8. Tighten the cable gland to secure against tension on the
cable.
NOTE:
This appliance must be earthed.
Fixed wiring installations must incorporate an all-pole disconnection switch.
9. Correctly locate the appliance into its final operating position and using a spirit level, adjust the legs
so that the appliance is level and at the correct height.
10. Connect the power supply to the appliance.
11. Check that the electrical supply is as shown in the Specificationssection.
THIS APPLIANCE MUST BE EARTHED. IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY A SUITABLY
QUALIFIED PERSON IN ORDER TO AVOID A HAZARD.
Rating Plate
Location