Installation
English24
English
STEP 4 Final Check
When installation is complete, conrm that:
The dryer is plugged into an electrical outlet and grounded properly.
The exhaust ductwork is connected and the joints are taped.
You have used rigid or stiff-walled exible metal duct material, not plastic exible duct.
The dryer is level and is sitting rmly on the oor.
The dryer starts, runs, heats, and shuts off properly.
Exhaust ducting guide
Ducting
1. Make sure the dryer is installed properly so the air exhausts freely.
2. Use 4-inch rigid metal ducts. Tape all joints including the dryer connection.
Never use lint-trapping screws.
3. To facilitate the exhaust, keep the ducts as straight as possible.
Cleaning
Clean all old ducts before installing the dryer, and make sure the vent ap opens and
closes freely. We recommend that you to clean the exhaust system annually or on a
regular basis.
WARNING
To prevent re, do not use plastic, thin-foil, or non-metal exible ducts of any kind.
Do not use a poor exhaust system because it slows down the dryer’s performance.
Do not use excessively long ducts that have multiple elbows.
Do not use crushed or clogged venting or ducts.
DV6900B_LED_WEB_Vent_EN.indd 24 2022/5/13 15:28:38