Installation
Instructions
Choosing The Right Location
Recommend Installation
Your installation location should meet the following requirements:
-Make sure that you install your unit on an even surface to minimize noise and
vibration.
-The unit must be installed near a grounded plug, and the Collection Tray Drain
(found on the back of the unit) must be accessible.
-The unit should be located at least 30cm (12”) from the nearest wall to ensure
proper air conditioning. The horizontal louver blade should be at least 50cm
(19.7”) away from obstacles.
-DO NOT cover the Intakes, Outlets or Remote Signal Receptor of the unit, as this
could cause damage to the unit.
50cm
19.7 inch
Energy Rating Information
How to Stay Cool with a New Portable Air Conditioner(For the models comply with the
requirements of Department Of Energy in US)
Because of a new federal test procedure for Portable Air Conditioners, you may notice that the cooling capacity
claims on portable air conditioner packaging are significantly lower than that of models produced prior to 2017.
This is due to changes in the test procedure, not to the portable air conditioners themselves.
The unit with 3 meters extended exhaust duct is running by using 2 exhaust ducts(Diameter:5.9inch, Length:59inch
+ Diameter: 5.12inch, Length: 59inch ) .The Energy rating and noise information for unit with 3 meters extended
exhaust duct is not assessed.(For some models)
NOTE
We recommend that operating the unit at room temperature below 95°F . Since there is a risk that the unit with 3
meters extended exhaust duct would not work at room temperature above 95°F under some extreme conditions,
such as the lower air intake be blocked for 50%.
The energy rating and noise information for this unit is based on the standard installation using an un-extended
exhaust duct without window slider adaptor (as shown in the Installation section of this manual). At the
same time, the unit must be operate on the COOL MODE and HIGH FAN SPEED by remote controller.
MODE Temperature Range MODE Temperature Range
Ambient Temperature Range For Unit Operating
Cool 17-35°C (62-95°F)
Dry
Heat(pump heat mode)
Heat(electrical heat mode) 13-35°C (55-95°F)
5-30°C (41-86°F)(select models only)
Exhaust Hose Installation
The exhaust hose and adaptor must be installed or removed in accordance with the usage mode. For
COOL,HEAT(heat pump type) or AUTO mode (select models only) must be installed exhaust hose.
For FAN, DRY or HEAT(electrical heat type) mode (select models only) must be removed exhaust hose.
30°C (86°F)(select models only)