Sunpentown WAS7000E 14" Portable Air Conditioner with 10000 BTU Cooling Capacity, 115 Volts

Owner’s Manual & Installation Manual - Page 11

For WAS7000E.

PDF File Manual, 32 pages, Read Online | Download pdf file

WAS7000E photo
Loading ...
Loading ...
Loading ...
Page 11
Installation
Instructions
Installation Instructions
Preparation
NOTE:
All the illustrations in the manual are for explanation purpose only. Your machine may be slightly different.
The actual shape shall prevail. The unit can be controlled by the unit control panel alone or with the remote
controller. This manual does not include Remote Controller Operations, see the <<Remote Controller
Instruction>> packed with the unit for details.
Design Notice
In order to ensure the optimal performance of our products, the design speci cations of the unit and
remote control are subject to change without prior notice.
front
control panel
remote signal receptor
horizontal louver control
lever(adjust manually)
vertical louver control
lever(adjust manually)
panel
Caster
recovery occurs. The recovery equipment shall be in good working order with a set of instructions
concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants.
In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall
be complete with leak-free disconnect couplings and in good condition. Before using the recovery
machine, check that it is in satisfactory working order, has been properly maintained and that any
associated electrical components are sealed to prevent ignition in the event of a refrigerant release.
Consult manufacturer if in doubt. The recovered refrigerant shall be returned to the refrigerant supplier
in the correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants
in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed,
ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant
does not remain within the lubricant. The evacuation process shall be carried out prior to returning the
compressor to the suppliers. Only electric heating to the compressor body shall be employed to
accelerate this process. When oil is drained from a system, it shall be carried out safely.
rear
handle
(both sides)
bottom tray
drain outlet
air filter
upper air intake
air outlet
lower air intake
drain outlet
Loading ...
Loading ...
Loading ...