8
TRUE
SPEC SERIES: STR, STA & STG
www.truemfg.com
CONFIGURATION (PILASTERS):
Each TRUE Specification Series (STR, STA, and STG) is available with
two pilaster configurations. Each configuration depends on the end
user preference. Multiple door units can have two configurations for
each section. See image 7.
INSTALLATION PROCEDURES (PILASTERS):
Install slotted thumb screws into threaded holes along the inside wall
of the cabinet.
Slide pilasters into position behind the slotted screws. Leave all of the
thumb screws loose for adjustments when installing tray slides.
It is critical to measure from the center of the square hole on the
front pilaster to the center hole of the rear pilaster. This measurement
should be 24 5/8" (625 mm) (see image 8). Do the same on the
opposite side of cabinet for single door. Make sure the measurement
of 24 5/8" (625 mm) is the same in the center pilasters in 2 and 3
door units. Tap the tray slides into the Pilasters with a rubber Mallet.
Angle & Rod Type shelving uses a 18 1/8" (460 mm) distance
between Pilasters. Universal Tray slides have a 21 1/4" (540 mm)
distance between Pilasters. See image 9.
After the pilasters are installed the Universal Tray, Angle Type Tray,
and Rod Style Tray Slides will slide into the pilasters. See images 1-6.
When disassembling or changing tray slides a rubber mallet may be
used to take out the different tray slides. Gently tap on the under side
of the tray slide to loosen it from the pilaster.
Type Kit #3 (Universal Tray Slide)
5 6
Type Kit #2 (Rod Style Tray Slide)
3 4
Type Kit #1 (Angle Type Tray Slide)
1 2