MAINTENANCE, CARE, CLEANING
CLEANING THE CONDENSER COIL
When using electrical appliances, basic safety precautions should be
followed, including the following. Disconnect power to unit.
TOOLS REQUIRED
CAUTION: Before performing service or maintenance make sure
louver grill is secured in open position. Use instructions and photos
below to secure louver grill.
1. Remove thumbscrews on the top of each cabinet end.
2. Lift louver grill (careful not to pull on any wires)
3. Reinstall thumbscrews
A. The thumbscrews should be put through louver grill holes
and fastened into previous position in cabinet end.
CAUTION: Make sure top louver grill is correctly seated in the
open position when servicing or cleaning.
B. When servicing is complete remove thumbscrews and
close louver grill. Then reinstall thumbscrews into original
location.
While cleaning condenser coil lift and hold top louvered grill.
Clean off accumulated dirt from the condenser coil with a
stiff bristle brush. Vacuum all dirt residue from the coil and
surrounding areas while holding the top louvered grill. Any
servicing to condensing unit remove top louvered grill. On top
of the cabinet are two screws are located on either side of the
louver grill. Remove these screws from the hinges and keep
them in a safe place while servicing the unit. These screws are
needed for later re-install of the louver grill.
Phillips Screwdriver
Stiff Bristle Brush
Adjustable Wrench
Air Tank or CO2 Tank
Vacuum Cleaner
Condenser Cleaning
Louver grill in upright positionThumbscrew location
Thumbscrews located
on cabinet ends