4.2 System status
Normal
1 2 3
4
5
6
1. LEVEL – Indicates the master gain of the system in dB. The range is from mute to +10 dB,
in 1 dB increments.
2. 1 - Indicates the current recalled preset number. There are five presets available for
storing and recalling.
3. E - Indicates that the current recalled preset has updated parameters and is not saved.
4. IN1 - Indicates in meter form the magnitude of signal present on INPUT 1.
5. IN2 - Indicates in meter form the magnitude of signal present on INPUT 2.
6. IN3 - Indicates in meter form the magnitude of signal present on INPUT 3.
LIMIT
LIMIT indication is displayed when gain reduction is being applied to the signal. This allows
the loudspeaker to continue operating while preventing the amplifier and components from
exceeding their functional capability. Levels operating continuously beyond the limiter
threshold must be avoided.
PK
When PK (peak) is indicated, the INPUT signal magnitude is higher than what the amplifier can
handle and is effectively clipped (distorted). Lower the volume of the signal source and/or
lower the INPUT LEVEL by rotating the corresponding INPUT LEVEL knob counter-clockwise.
The PK status must be avoided at all times. Even momentary bursts of clipped signal can
severely damage system components.