Westinghouse WFE9515SD

User Manual - Page 4

For WFE9515SD.

PDF File Manual, 21 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
6 7INSTALLATION OF THE APPLIANCEINSTALLATION OF THE APPLIANCE
Cabinet requirement
Model WFE9515SD is designed to fit into a 900mm
wide gap between standard kitchen cabinets. The
appliance integrates with the kitchen cabinets by
matching the height, depth and kick panel. The cooker
may also be installed at the end of a line of benches
or with a free space either side. In addition, a slot-in
type installation is catered for allowing a continuous
cabinetry kick panel to be used.
WARNING
The cooker must be installed and serviced only
by an authorised person.
A Certificate of Compliance MUST be supplied to
be kept by the customer.
The packing materials must be removed before
you install the cooker.
The surrounding kitchen cabinets must be able
to withstand 85°C. Electrolux WILL NOT accept
responsibility for damage caused by installation
into kitchen cabinets which cannot withstand 85°C.
The pipes used for installation MUST have sufficient
loops so the cooker can be moved for service
(gas models).
The vents, openings and air spaces MUST NOT
be blocked.
Two anti-tilt brackets are supplied and stored in the
base of the packaging
The anti-tilt brackets and chain or front stops
MUST be installed to avoid accidental tipping
(freestanding and slot-in models).
You MUST NOT lift or pull the cooker by the
door handle.
The cooker MUST be checked every five years.
If the supply cord is damaged,it must be replaced
by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
The appliance must not be installed behind a
decorative door in order to avoid overheating.
Due to the weight (95-100kg) and size of the
cooker, 2 persons are required to install it.
Gas model clearance requirements
Ensure the appliance is installed in accordance with
AS/NZS 5601.1 or AS/NZS 5601.2 with regard to
clearances to combustible surfaces and materials,
and clearances to rangehoods and exhaust fans,
to ensure clearances of 200mm from burners to
vertical combustible surfaces observe the minimum
dimension of 100mm from each side of the cooker to
combustible surfaces.
Clearances to combustible surfaces may be reduced
if combustible surfaces are protected in accordance
with AS/NZS 5601.1, or AS/NZS 5601.2.
When setting the cooker height, ensure the top of
the cooker is at least 10mm higher than the level of
the benchtop.
Dimensions
600mm minimum
vertical clearance
from combustible
surfaces
Gas hob 910mm
(adjustable 910-930mm)
600mm
895mm
60mm
Splashback
The splashback is secured to the back of the cooker.
REMOVE the splashback before installing the feet.
Undo this screw
to remove the
splashback.
Re-attach the
screw afterwards
INSTALLATION OF THE APPLIANCE
Freestanding installation
Cabinet construction for freestanding installation
The freestanding type installation requires four screw-in
feet to be installed before it can be fitted in between
cabinets, with cabinets on one side or without adjacent
cabinets. There is no clearance requirement to adjacent
side cabinets.
To ensure cooker stability, the anti-tilt brackets must
be installed.
F
our screw-in feet are supplied with the appliance and
can be found in the accessories pack in the oven.
WFE9515SD is supplied with a clip-on kick panel.
900mm minimum
755mm NOM
900mm NOM
600mm
both sides
INSTALLATION OF THE APPLIANCE
Loading ...
Loading ...
Loading ...