Connecting Temperature Sensor
The temperature sensor will have a green housing connector on one end and a metal probe
on the other. Simply align and connect the green housing to the BTS terminal on the DCDC.
Place the probe end of the sensor near or on top of the battery to monitor temperature in the
area.
Connecting IGN Signal Wire
Standard/Traditional Alternator–has a fixed voltage when charging (Do not connect IGN wire)
Smart Alternator—has a controlled charging output based on operating conditions.
Variable. (Requires IGN signal wire)
There are two ports on the green IGN connector housing. Both ports have a positive polarity, so
only one connection is required from either port.
Connect the positive line to one of green housing ports on the IGN port. You will need to open
the wire terminal utilizing the screws on top of the green housing. You will then connect the
positive line of the IGN to the ignition circuit.
Connect IGN to Vehicle Ignition