USER MANUAL
24
Select parameters of series-parallel connection
Select parameters of CH1 and CHI2 will be back to default automatically (voltage: 0V,
current: 3.1A) after connect in series.
Select the total current value of CH1 and CH2 will be set to 6.2A automatically, and voltage
value is still 0V after connect in parallel.
Select limit voltage in series-parallel connection
If limit voltage values of CH1 and CH2 are set as 20V, 25V before series-parallel
connection:
The voltage range will be 45V (sum of the two channels) after connect in series;
The voltage range will be 20V (min value of the two channels) after connect in parallel;
Notice: the status of CH1 and CH2 are OFF when change connection mode; in the
meanwhile, voltage will be back to 0V; and you need to reset output parameters.
However, voltage, current and output status of CH3 could not be affected.
After connect in series/parallel, save and recall function are forbidden. When select
series or parallel connection, hardware connection is needed.
TRAC (sync output setting)
The TRACK function of IT6302 could change voltage/current of CH1, CH2 in scale.
When select it, CH1 and CH2 could be set as synchronous mode; choose “On”
status, and press to confirm; and then press
Esc
to exit.
Please set voltage and current of CH1 and CH2 before this setting. The relevant
parameters of other channels will be changed in scale when one parameter changed in the
synchronous mode.
For example, set voltage and current of CH1 and CH2 as follows, CH1: 4V, 1A; CH2: 8V,
2A. Press (Shift) + (Menu)into Menu, and press to select TRAC, VFD will