ITECH IT6302 30V 3A Triple Output DC Power Supply

Manual - Page 14

For IT6302.

PDF File Manual, 28 pages, Read Online | Download pdf file

IT6302 photo
Loading ...
Loading ...
Loading ...
IT6302 user manual
USER MANUAL
14
2.2 Additional features
Suggested calibration frequency: 1time /Year
Line voltage supported (can be selected by the switch on the rear panel)
Option 01: 220VAC ± 10%, 47 to 63 Hz
Option 02: 110 VAC ± 10%, 47 to 63 Hz
Max input power
Module
IT6302
Power
750VA
Cooling
Fans
Operation temperature
0 to 40 °C
Storage temperature
-20 to 70 °C
Environmental conditions
Indore use only, max humidity 80%, no condensation.
Setup stability-8h
(%of Output +Offset)
Voltage
0.01%+10mV
Current
0.1%+5mA
Readback stability-8h
(%of Output +Offset)
Voltage
0.01%+20mV
Current
0.1%+5mA
Fuse specification
6.3A(110V)/3.15A(220V)
Command Response
Time
20mS (Typical)
Power Factor
0.7 (Typical)
Maximum input current
4.5A(110V)/2.2A(220V)
Maximum input
apparent power
700VA
Storage temperature
-10~70
Protective function
LVP/OTP
standard Interface
COM(TTL)
Isolation
( output to ground)
200V
Working temperature
0~40
Dimension ( mm)
214.5mmW*88.2mmH*354.6mmD
Weight( net)
7.1Kg
Loading ...
Loading ...
Loading ...