Turbofan E32D4 Full Size Tray Digital Electric Convection Oven

Installation Operation Manual - Page 17

For E32D4.

PDF File Manual, 31 pages, Read Online | Download pdf file

E32D4 photo
Loading ...
Loading ...
Loading ...
Programming
15
8. SET MOISTURE OPTION (H-0 - H-5).
*Upper Display flashing*
Rotate Tempknob to select Moisture setting required.
‘+’ to increase moisture setting.
-to decrease moisture setting.
(Refer to Operation section, Moisture Mode Settings’, for additional explanation of moisture level adjustment).
Press Pkey to confirm Moisture setting. Controller will step to Fan Speed setting.
9. SET FAN SPEED (LO - HI).
Upper Display shows
*Lower Display Flashing with current Fan setting*
Rotate Timerknob to select desired fan option, shown on Lower Display.
Press Pkey to confirm fan speed setting. Controller will step to Alarm setting for End of Stage.
NOTE: If Multi-Stage Cooking is disabled, (Operator setting StG- set to no’), the controller will exit the Programming
Mode after the Pkey is pressed to confirm fan speed setting.
10.SET ALARM FOR END OF STAGE (‘ON-OFF’).
Upper Display shows
*Lower Display flashing with current alarm setting*
Rotate Timerknob to select desired alarm state which will be shown on the Lower Display.
ON- Alarm sounds at completion of the cooking stage, the program is paused awaiting user action. Without any input, the
program will automatically resume after 1 minute.
- Press Timer-Start/Stopkey to stop the alarm, resume cooking and to continue to the next cooking stage.
OR
- Open oven door to stop alarm. Close door and press Timer-Start/Stopkey to continue cooking and to continue on to the
next cooking stage.
OFF- Oven continues on to the next cooking stage without sounding an alarm.
NOTE: Regardless of the setting applied to the last stage of the program, a Cook Time Completed Alarm will sound to indicate the
end of the program.
Press Pkey to confirm alarm option. Alarm will sound to confirm that all stage parameters have been set.
Repeat Step 1 to Step 10 to program additional stages.
11.EXIT PROGRAMMING MODE.
Press and hold Pkey for 3 seconds until alarm sounds to exit the Programming Mode.