QUESTIONS IS BE RUN INTO IN WELDING
Fittings, welding materials, environment factor, supply powers maybe have something to do with
welding. User must try to improve welding environment.
AArcing-striking is difficult and easy to pause
1) Make sure the earth cable clincher connects the work piece well.
2) Check each connecting point connected or not.
BOutput current can not reach rated volume
That supplied voltage is different from the rated will lead to unconformity of the output current and
the adjusted current. When Supplied voltage lower than the rated, the max output current will be lower
than the rated.
CCurrent is not stabilizing when machine is been operating.
It has something with factors as following:
1) Electric wire net voltage has been changed
2) There is harmful interference from electric wire net or other equipment
D Welding gap has air hole.
1) Check the gas supply loop leaks or not.
2) Surface of mother material has oil, stain, rust, lacquer or other impurity.
MAINTENANCE
CAUTION
Before Maintenance and checking, power must be turned off, and before
Opening the housing, make sure the power plug is pulled off..
1 Remove dust by dry and clean compressed air regularly, if welding machine is operating in
environment where is polluted with smokes and pollution air, the machine need remove dust
everyday.
2Pressure of compressed air must be inside the reasonable arrangement in order to prevent damaging
to small components of inter-machine.
3Check inter circuit of welding machine regularly and make sure the cable
Circuit is connected correctly and connectors are connected tightly (especially insert connector and
components). If scale and loose are found, please give a good polish to them, then connect them
again tightly.
4Avoid water and steam enter into inter-machine, if them enter into machine,
Please dry inter-machine then check insulation of machine.
5If welding machine will not be operated long time, it must be put into packing
Box And store in dry environment.
6When wire machine operates for every 300 hours, the electric carbon brush and
armature rectifier should be polished, the reducer should be cleaned, and
lubricator should be added to the turbo and bearing.