Kickback and Related Warnings:
Kickback is a sudden reaction to a pinched or snagged
rotating wheel, backing pad, brush or any other accessory.
Pinching or snagging causes rapid stalling of the rotating
accessory which in turn causes the uncontrolled power tool
to be forced in the direction opposite of the accessory’s
rotation at the point of thebinding.
For example, if an abrasive wheel is snagged or pinched by
the workpiece, the edge of the wheel that is entering into the
pinch point can dig into the surface of the material causing
the wheel to climb out or kick out. The wheel may either
jump toward or away from the operator, depending on
direction of the wheel’s movement at the point of pinching.
Abrasive wheels may also break under theseconditions.
Kickback is the result of power tool misuse and/or incorrect
operating procedures or conditions and can be avoided by
taking proper precautions as givenbelow.
a ) Maintain a firm grip with both hands on the
power tool and position your body and arms
to allow you to resist kickback forces. Always
use auxiliary handle, if provided, for maximum
control over kickback or torque reaction during
start‑up. The operator can control torque reactions or
kickback forces, if proper precautions aretaken.
b ) Never place your hand near the rotating
accessory. Accessory may kickback over yourhand.
m ) Never lay the power tool down until the accessory
has come to a complete stop. The spinning
accessory may grab the surface and pull the power tool
out of yourcontrol.
n ) Do not run the power tool while carrying it at your
side. Accidental contact with the spinning accessory
could snag your clothing, pulling the accessory into
yourbody.
o ) Regularly clean the power tool’s air vents. The
motor’s fan will draw the dust inside the housing and
excessive accumulation of powdered metal may cause
electricalhazards.
p ) Do not operate the power tool near flammable
materials. Sparks could ignite thesematerials.
q ) Do not use accessories that require liquid
coolants. Using water or other liquid coolants may
result in electrocution orshock.
r ) When starting the tool with a new or replacement
wheel, or a new or replacement wire brush
installed, hold the tool in a well protected area
and let it run for one minute. If the wheel has
an undetected crack or flaw, it should burst in
less than one minute. If the wire brush has loose
wires, they will be detected. Never start the tool
with a person in line with the wheel. This includes
theoperator.
s ) Use of accessories not specified in this manual
is not recommended and may be hazardous.
Use of power boosters that would cause the tool
to be driven at speeds greater than its rated speed
constitutesmisuse.
Just because the accessory can be attached to your
power tool, it does not assure safeoperation.
e ) The rated speed of the accessory must be at least
equal to the maximum speed marked on the
power tool. Accessories running faster than their rated
speed can break and flyapart.
f ) The outside diameter and the thickness of your
accessory must be within the capacity rating of
your power tool. Incorrectly sized accessories cannot
be adequately guarded orcontrolled.
g ) Threaded mounting of accessories must match
the grinder spindle thread. For accessories
mounted by flanges, the arbor hole of the
accessory must fit the locating diameter of the
flange. Accessories that do not match the mounting
hardware of the power tool will run out of balance,
vibrate excessively and may cause loss ofcontrol.
h ) The dimensions of the accessory mounting must
fit the dimensions of the mounting hardware of
the power tool. Accessories that do not match the
mounting hardware of the power tool will run out
of balance, vibrate excessively and may cause loss
ofcontrol.
i ) Do not use a damaged accessory. Before each use
inspect the accessory such as abrasive wheels for
chips and cracks, backing pad for cracks, tear or
excess wear, wire brush for loose or cracked wires.
If power tool or accessory is dropped, inspect
for damage or install an undamaged accessory.
After inspecting and installing an accessory,
position yourself and bystanders away from the
plane of the rotating accessory and run the power
tool at maximum no‑load speed for one minute.
Damaged accessories will normally break apart during
this testtime.
j ) Wear personal protective equipment. Depending
on application, use face shield, safety goggles
or safety glasses. As appropriate, wear dust
mask, hearing protectors, gloves and workshop
apron capable of stopping small abrasive or
workpiece fragments. The eye protection must
be capable of stopping flying debris generated by
various applications. The dust mask or respirator must
be capable of filtrating particles generated by the
particular application. Prolonged exposure to high
intensity noise may cause hearingloss.
k ) Keep bystanders a safe distance away from work
area. Anyone entering the work area must wear
personal protective equipment. Fragments of
workpiece or of a broken accessory may fly away and
cause injury beyond immediate area ofoperation.
l ) Hold the power tool by insulated gripping
surfaces only, when performing an operation
where the cutting accessory may contact hidden
wiring. Cutting accessory contacting a "live" wire may
make exposed metal parts of the power tool "live" and
could give the operator an electricshock.