BURNER ADJUSTMENT
Flames should be blue and stable with no yellow tips, excessive noise or lifting (Note: LP
units may have some yellow tipping). If any of these conditions exist, check the air shutter
and burner ports are clear. If cleaning these does not improve performance, the air shutter
for the outer burner can be adjusted as below.
yellow tips
noisy/lifting
blue + stable
Flame height adjustment
1
3
4
2
With a screw driver, loosen the lock screw
on the face of the air shutter. If the flame
is yellow turn the air shutter counter-
clockwise, if the flame is noisy and tends
to lift turn the air shutter clockwise.
Light to check adjustment. If the flame
is blue and stable, tighten the air shutter
screw and replace all parts. If flame is still
unstable, repeat the above steps.
Ensure the power burner is
OFF and cool.
To access the air shutter, remove the
trivets and burner hob. The hob can
be removed by unscrewing the four
screws from each corner.
The burner should not be removed.
BURNER TOP VIEW