14
BURNER ADJUSTMENT
The valve for the outer burner feature an adjustable low setting. Due to fluctuations in gas
pressure, or heating value you may feel it necessary to increase or decrease gas flow in the
low position.
1
3
4
2
Remove the dial.
While holding the valve shaft with pliers,
insert a flat-tipped screwdriver into the
shaft and, while viewing the burner, adjust
to a minimum stable flame.
Push in and hold the outer burner
dial for 2 seconds before turning
to HI. Hold for 10 seconds to light
the selected burner.
Turn the control dial counter-
clockwise to the lowest setting.
BEZEL FRONT VIEW
Low flame adjustment