CONVERTING POWER UNIT FROM
CYCLONIC OPERATION TO A
BAGGED SYSTEM (DEBRIS BAG
INCLUDED)
The NC3500, NCKIT3500, NCKIT3500HD, NC4500, NC5500,
NCKIT5500, NCKIT5500HD, HHKIT650A, NT650A1,
NT650E1, NT700A and NT700E units are factory shipped
ready for use in cyclonic mode, but due to their hybrid design,
they can also be operated with a disposable bag (391C). The
bag adapter (included with the unit) must be installed if the
disposable bag will be used. Follow these steps:
Remove the pail from unit by releasing both side latches,
pulling them out and then pushing them up. Detach the pail
from unit.
Assemble the bag
adapter to the intake
elbow. Align triangle
with small inclined
stud.
Tighten the junction
using the screw and
nut (included in parts
bag).
Unfold the disposable bag and grasp its collar where
indicated. Insert over bag adapter. Be careful not to tear the
bag. Ensure the collar is positioned between the taper ring
and the bag stopper on the bag adapter (see illustration
below). Put the pail back in place.
MOUNTING THE POWER UNIT
Carefully remove debris pail from power unit. Make sure bag
is properly installed in power unit (if need be). Remove the
installation kit and securely reinstall debris pail.
Refer to illustration below to maintain minimum walls and
floor clearance dimensions.
Position and install the wall mounting bracket with the
provided screws. Refer to illustration on next page for
proper mounting dimensions.
POWER UNIT INSTALLATION
18” minimum
above floor
12” minimum
from ceiling
12
minimum
TOP VIEW
FRONT VIEW
MINIMUM CLEARANCE DIMENSIONS
12
minimum
AD0039A
CAUTION
Ensure to screw the wall mounting bracket directly
to a wall stud for a solid installation.