Broan NC3500 NuTone 650 Air Watts Central Vacuum System

Installation and User Guide - Page 12

For NC3500. Also, The document are for others Broan models: NC1500, NC4500, NC5500, NCKIT1500, NCKIT3500, NCKIT5500, NCKIT1500HD, NCKIT3500HD, NCKIT5500HD, HHKIT550A, HHKIT550E, HHKIT650A, NT550A, NT550E, NT650E1, NT650A1, NT700E, NT700A

PDF File Manual, 44 pages, Read Online | Download pdf file

NC3500 photo
Loading ...
Loading ...
Loading ...
12
DISPOSABLE BAG REPLACEMENT
To remove the disposable bag, release both latches on
sides of the unit by pulling out and then pushing up. Remove
the pail from unit. Grasp the edges of the bag collar and pull
down. The bag will slide off easily. Do not pull on the bag.
Unfold the new bag.
Grasp collar where indicated on the new bag and insert over
bag adapter. Be careful not to tear the bag. Ensure the collar
is positioned between the taper ring and the bag stopper on
the bag adapter (see illustration below). Put the pail back in
its place.
PERMANENT FILTER
(NC3500, NCKIT3500, NCKIT3500HD,
NC4500, NC5500, NCKIT5500,
NCKIT5500HD, HHKIT650A, NT650A1,
NT650E1, NT700A AND NT700E POWER
UNITS ONLY)
This filter protects the motor and stops small particles from
escaping to the outside of the power unit wihout the need to
replace it. The filter cleans itself by moving up when the power
unit starts, and dropping down when the unit is turned off.
Under normal use, there is no need to maintenance this filter.
It is possible to remove it to inspect the motor foam filter, or
to replace it if ever it has been damaged (by sharp debris, for
example).
REMOVAL AND INSTALLATION OF
PERMANENT FILTER (NC3500, NCKIT3500,
NCKIT3500HD, NC4500, NC5500,
NCKIT5500, NCKIT5500HD, HHKIT650A,
NT650A1, NT650E1, NT700A AND NT700E
POWER UNITS ONLY)
Remove the pail from unit.
To remove the permanent
filter, use pull tab (A)
located on edge of filter to
pull and loosen filter from
inlet chamber wall. Squeeze
from both sides of the filter
to the center of the housing.
Then, carefully remove it
from the unit.
Squeeze the filter in order
to move it past the inlet
opening (B) Let the filter
bear against the unit wall
by releasing the pressure.
Make sure to place the rigid
ring in its groove to ensure
proper sealing.
NOTE: Make sure the filter is
installed so that the pull
tab (A) is accessible
for future filter removal.
MOTOR FOAM FILTER
(ALL UNITS)
A motor foam safety filter, located at the top of the vacuum
chamber provides protection against dirt being pulled into the
motor if the disposable bag or permanent filter should accidentally
be torn. This filter should be checked and cleaned if necessary
when replacement bag is installed, or when permanent filter
is removed (NC3500, NCKIT3500, NCKIT3500HD, NC4500,
NC5500, NCKIT5500, NCKIT5500HD, HHKIT650A, NT650A1,
NT650E1, NT700A and NT700E units only). Simply brush filter
clean. If the filter is excessively soiled, hand wash in a water
and mild detergent solution, rinse and let it dry completely on
a flat surface before reinstalling.
REMOVING
MOTOR FOAM
FILTER
Remove the debris pail
and disposable bag or
permanent filter. Lift the
center of the wire retaining
the motor foam filter and
slide the filter out of its
location.
REINSTALLING
MOTOR FOAM
FILTER
To reinstall the motor foam
filter, reverse the steps
described above.
AO0081
TAPER RING
BAG STOPPER
OPERATION AND MAINTENANCE (CONT'D)
AD0084
A
AA0005
A
CAUTION
Be sure to reinstall filter properly. Appropriate
location is critical to insure proper protection of
the motor.
AD0085
B
CAUTION
Operating the power unit without the motor foam
filter will void the warranty.
AD0086
Loading ...
Loading ...
Loading ...