Operation
12 12
On oven start-up the controller defaults to the following settings:-
Oven Temperature is set to 150°C (325°F).
Refer Controller - Operator Settingssection to change this start-up temperature.
Oven Timer is not set, display shows - - -.
Moisture Setting is setting to Manual Injection.
1. CONNECT CORE TEMP PROBE.
Connect Core Temp Probe to connector on lower right side of
control panel, will be displayed on Lower Display.
2. SET OVEN TEMPERATURE.
Rotate Tempknob to select temperature required.
+ to increase the temperature (Max. 260°C / 500°F).
- to decrease the temperature (Min. 60°C / 140°F).
The oven will commence heating to the displayed set temperature.
3. SET CORE PROBE TEMPERATURE.
Rotate Timer Knob to set the desired core probe temperature.
+ to increase temperature (Max. 90°C / 194°F).
- to decrease temperature (Min. 50°C / 122°F).
Once Core Probe Set Temperature is set, Lower Display will alternately flash
between and Core Probe Set Temperature.
Timer-Start/StopLED is Off’, indicating that cooking has not yet started.
4. SET MOISTURE MODE.
Press and hold Steamkey for 3 seconds.
Rotate Tempknob to select desired moisture level (H-0 to H-5).
Press Steamkey to confirm settings.
NOTE: Refer to Moisture Mode Settingsat start of this section for additional
explanation of moisture level adjustments.
5. START CORE TEMP MODE COOKING.
Press Timer-Start/Stopkey to start Core Temp Mode cooking. Timer-
Start/StopLED is Onduring Core Temp Mode cooking. Lower Display
will alternately flash between and Core Probe Set Temperature
during cooking.
6. CANCELLING CORE TEMP ALARM (CORE TEMP SETTING REACHED - COOKING COMPLETE).
When Core Probe Set Temperature is reached, an alarm will sound and the Lower Display will flash.
- Press Timer-Start/Stopkey to cancel alarm, oven will continue cooking at Oven Set Temperature. Display will show Oven
Set Temperature and Core Probe Set Temperature.
- Alternatively, open oven door to cancel alarm and turn Offfan and heating. Close oven door to resume cooking at Oven
Set Temperature. The display will revert to the Oven and Core Probe Set Temperatures.
NOTE: Any of the above settings can be adjusted during cooking operation by using the above controls and keys.
Viewing Actual Oven and Core Temperatures. During cooking, press Tempkey to check Oven Actual
Temperature (Upper Display) and Core Probe Actual Temperature (Lower Display). Actual temperatures will display for 5
seconds before display reverts to show Oven Set Temperature (Upper Display) and Core Probe Set Temp (Lower Display).
Exiting Core Temp Cooking Mode. Disconnect Core Probe from connector on lower right side of control
panel. Lower Display and Timerknob will revert to normal Timer Mode operation.
Timer-Start/
StopLED is On
when Cook Mode
in Progress.
In Core Temp
Mode, pressing
Tempkey will
also display Core
Probe Actual
Temperature on
Lower Display.
In Core Temp
Mode, the Timer
knob is used to
set Core Probe
Temperature.
In Core Temp
Mode, the Lower
Display will
alternate
between CPand
the Core Probe
Set Temperature.
Loading ...