Service Manual - Page 47

For 1316482. Series: FTXS-L Series

Loading ...
Loading ...
Loading ...
Main Functions SiUS091133
37 Function and Control
1.9 ECONO Operation
Outline ECONO operation reduces the maximum operating current and the power consumption.
This operation is particularly convenient for energy-saving-oriented users. It is also a major bonus
for those whose breaker capacities do not allow the use of multiple electrical devices and air
conditioners.
It is easily activated from the wireless remote controller by pushing the [ECONO] button.
When this function is activated, the maximum capacity also decreases.
The remote controller can send the ECONO command when the unit is in COOL, HEAT, DRY, or
AUTO operation. This function can only be set when the unit is running. Pressing the [ON/OFF]
button on the remote controller cancels the function.
This function and POWERFUL operation cannot be used at the same time. The latest command
has the priority.
ECONO Operation
(R9288)
Normal
Maximum during normal operation
Maximum during ECONO operation
Time
Power
consumption
and current
Loading ...
Loading ...
Loading ...