SiUS091133 Outdoor Unit: RXS15/18LVJU
Removal Procedure 294
4
Release the fan motor
lead wire from the
groove and the 2 hooks
of the partition plate.
5
Remove the nut of the
outdoor fan.
Nut size: M6
Step
Procedure Points
(R16764)
(R16796)
(R16797)
Outdoor fan
(R16787)
(R16985)
10 mm
(0.39 inch)