6.4 Disassemble the push handle
1. Put the bowl on a smooth surface to
facilitate the removing of the tap.
Pull the "U" towards you and push the tap
with your other hand.
2. Unlock the spring, hold it down, push
horizontally and finally release it.
3. Unscrew the bar from the tap.
4. Hold down the two rubber flanges, and
separate the red rubber from it.
All parts must be washed with hot water
and soap, and fully air dried before being
re-assembled.
6.5. Wash and disinfect the components
All previously removed parts must be
thoroughly cleaned and disinfected.
Important note: Disinfection procedures
must comply with the machine operation
guidelines.
Please follow the instructions below to
ensure proper disinfection:
1. Dispense the antiseptic solution into the
container (2% sodium hypochlorite mixed
with water)
2. Thoroughly wash the bowl, lid and
evaporator with a soaked sponge.
3. Thoroughly clean with water
4. Pour disinfectant into another container
5. Dip the disassembled parts into the
disinfectant
6. Soak the parts in disinfectant for 30
minutes
7. Wash thoroughly with water again
8. Air dry the parts at a clean place
9. Reassemble as described in section 7.5
10. Rinse thoroughly with water before
using the machine
Caution: Do not immerse the lid with the
lamp in any solution. Before cleaning and
disinfecting the lid, please remove the lid
as described in the previous section. In
order to properly clean the lamp cover,
these steps must be followed:
1. Wipe the bottom of the lid (the part
contact with the machine) with a clean,
damp cloth
2. Wipe the outside of the machine with a
clean, damp cloth,
3. Use a disinfectant soaked sponge to
disinfect the bottom of the lid,
And be sure not to wet the lid's interface
with the machine
4. Allow operation for 30 minutes
5. Rinse twice or more. Only the bottom of
the lid needs to be wiped with clean water
sponge.
6. Put the lid on a clean flat surface to dry.
First, dry the bottom and wipe the external
parts with a clean cloth.
7. Install the lid back after the bowl has
been cleaned and disinfected. Never clean
the machine when the lid is installed on it.
6.6 Reassemble the cleaned parts
All cleaned and disinfected components
must be carefully reinstalled, and
components must be fully lubricated for
the machine to work more efficiently.
Clean the tray and grid separately with
warm water
Dry all the parts
Put the grid back over the tray
Install the seal ring of the mixer shaft as
shown