38730-0-031838730-0-0318
GAS REQUIREMENTS
GAS SAFETY INSTRUCTIONS
Your natural gas grill is designed for use with
natural gas (NG) or LP gas. The gas pressure
Regulator supplied with this appliance must
be installed and used on your grill. The
unit and Regulator are set to operate with
an outlet pressure of 4" W.C. for NAT gas.
When using LP gas, the regulator and grill
orices must be connected to LP gas. (See
converting your gas grills section).
Install a Shut-Off Valve at the gas supply
source outdoors at a point after the gas
pipe exits the outside wall and before the
ex-line or quick-disconnect hose. Or install
it at the point before the gas line piping
enters the ground.
Pipe sealing compound or pipe thread tape
resistant to the action of natural gas must be
used on all male pipe thread connections.
Disconnect your gas grill from fuel source
when the gas supply is being tested at high
pressures.
This gas grill and its individual shutoff valve
must be disconnected from the gas supply
pipe system during any pressure testing of
that system at pres-sure in excess of 1/2 psi
(3.5kpa). Turn off your gas grill when the gas
supply is being tested at low pressures. The
grill must be isolated from the gas supply
pipe system by closing its individual manual
shutoff valve during any pres-sure testing
of the gas supply pipe system at pressures
equal to or less than 1/2 psi (3.5kpa).
CHECK ALL CONNECTIONS
FOR GAS LEAKS
Never test for leaks with an open ame.
Prior to rst use and at the beginning
of each season, you must check for gas
leaks. Follow these three steps:
1. Make a soap solution by mixing one part
liquid detergent and one part water.
2. Turn the grill Control Knobs to their full
OFF positions. Next, turn the gas ON at
the source.
3. Apply the soap solution to all gas
connections. If bubbles appear in the
soap solution the connections are not
properly sealed. Check each tting and
tighten or repair as necessary.