If water enters the unit, switch off the circuit breaker then unplug the unit from the power outlet.
Isolate the power supply by disconnecting the power plug from the socket, then contact
a qualified technician.
This appliance is not intended for use by persons (including children) with reduced physical, sensory,
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning the use of this appliance by an adult, guardian, or a person responsible for
their safety.
Children should be supervised to ensure that they do not play with the appliance.
Do not operate your Air Conditioner in a wet room such as a bathroom or laundry room.
Contact any authorized service technician for the repair or maintenance of this unit.
Do not operate the front louvers with your hands. It my lead to injury.
Avoid Accidents
To reduce the risk of fire, electrical shock, or injury when using your Air Conditioner, follow these basic
precautions:
Ensure that the electrical service is adequate for the model you have. This information can be found
on the rating label, which is located on the side of the cabinet and behind the grille.
If the Air Conditioner is to be installed on a window, clean both sides of the glass first. If the window
is a triple track and it has a screen panel included, remove the screen completely before installation.
Ensure that the Air Conditioner has been securely and correctly installed according to this manual's
installation instructions. Save this manual for possible future use in case you may need to remove
or reinstall this unit. When handling the Air Conditioner, be careful to avoid cuts from the sharp metal
fins on the front and rear coils.
Electrical Information
The complete electrical rating of your new Air Conditioner is stated on the rating label. Refer to the rating
when checking the electrical requirements.
Be sure the Air Conditioner is properly grounded. To minimize shock and fire hazards, proper
grounding is important. The power cord is equipped with a three-prong grounding plug for protection
against shock hazards.
The Air Conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you
intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a
qualified electrician install the proper receptacle. Ensure the receptacle is accessible after the unit
installation.
Do not run the Air Conditioner without a side protective cover in place. The absence of a side
protective cover could result in mechanical damage within the Air Conditioner.
Do not use an extension cord or an adapter plug.
OPERATION OF THE CURRENT DETECTION DEVICE
The power cord contains a current device that senses damage to the power cord. To test your power cord,
do the following:
1. Plug in the Air Conditioner.
2. The power supply cord will have TWO buttons on the plug head. Press the TEST button. You will
notice a click as the RESET button pops out.
3. Press the RESET button. Again you will notice a click as the button engages.
4. The power cord is now supplying electricity to the unit.
NOTE: Performance may be reduced outside of these operating temperatures:
Cooling
Operation
Outdoor temperature: 64–109°F (18–43°C)
Indoor temperature: 62–90°F (17–32°C)
WARNING
• Do not use other means to accelerate the defrosting process, or other means to clean this unit,
unless recommended by the manufacturer.
Do not store this appliance in a room with continuously operating ignition sources.
Do not pierce or burn this unit.
Be aware that the refrigerants used in this appliance may be odorless.
Compliance with national gas regulations shall be observed.
Keep ventilation openings clear of obstructions.
When not in use, properly store this appliance to prevent serious damage.
This appliance should be operated only in a well-ventilated area, with the correct room size as
specified for proper appliance operation.
Any person who is involved with working on or breaking into a refrigerant circuit should hold a
current valid certificate from an industry-accredited assessment authority, which authorizes their
competence to handle refrigerants safely in accordance with an industry recognized assessment
specification.
Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance
and repair requiring the assistance of other skilled personnel shall be carried out under the
supervision of the person competent in the use of flammable refrigerants.
Please follow the instructions to handle, install, or clean the Air Conditioner to avoid any damage
or hazard. Flammable Refrigerant R32 is used within this Air Conditioner.
During maintenance or disposal of the Air Conditioner, the refrigerant (R32) shall be recovered
properly. Do not discharge it to the air directly.
Do not place the Air Conditioner around any open fire or device like switch which may generate
sparks to avoid a fire hazard.
Store or maintain the Air Conditioner according to instructions found on this manual to avoid
mechanical damage.
Flammable refrigerant – R32 is used in this Air Conditioner. Please follow the instructions carefully
to avoid hazards.
Do not use this unit for any purpose other than its intended use.
1. Transport of Equipment Containing Flammable Refrigerants
Check the local transport regulations.
2. Marking of Equipment Using Signs
Check the local regulations.
3. Disposal of Equipment Using Flammable Refrigerants
Check the national regulations.
4. Storage of Equipment
The storage of this equipment should be in accordance with the manufacturer's instructions.
CAUTION: Risk of fire/
flammable materials
IMPORTANT NOTE: Read this manual carefully before
installing or operating your new air conditioning unit.
Keep this manual for future reference.