Smeg PX375 Hob Stainless steel

User manual - Page 15

For PX375.

PDF File Manual, 20 pages, Read Online | Download pdf file

PX375 photo
Loading ...
Loading ...
Loading ...
38 - INSTALLATION 91477A872/A
It is possible to identify the available gas types based on the country the appliance is to be installed
in. Refer to the heading number to identify the correct values in the “Burner and nozzle characteristics
tables".
Burner and nozzle specifications tables
60 cm models:
3 Natural Gas G25.1
G25.1
25 mbar
4 Natural Gas G2.350
G2.350
13 mbar
5 LPG G30/31
G30/31
28-30/37 mbar
••••••
G30/31
30/30 mbar
••
6 LPG G30/31
G30/31
37 mbar
7 Town Gas G110
G110
8 mbar
••
Gas types IT
GB
IE
FR
BE
ES PT RU
SE
DK
FI
NO
PL HU
1 Natural Gas G20 - 20 mbar AUX SR RR UR
Rated heating capacity (kW) 1.10 1.80 2.60 3.50
Nozzle diameter (1/100 mm) 73 95 115 132
Reduced flow rate (W) 400 500 750 1600
Primary air (mm) 1 1.5 1 1
2 Natural Gas G20 - 25 mbar AUX SR RR UR
Rated heating capacity (kW) 1.10 1.80 2.60 3.50
Nozzle diameter (1/100 mm) 73 87 110 126
Reduced flow rate (W) 400 500 750 1600
Primary air (mm) 1 1 1 1.5
3 Natural Gas G25.1 - 25 mbar AUX SR RR UR
Rated heating capacity (kW) 1.00 1.80 2.60 3.50
Nozzle diameter (1/100 mm) 76 98 123 145
Reduced flow rate (W) 400 500 750 1600
Primary air (mm) 1 1 0.5 1.5
4 Natural Gas G2.350 - 13 mbar AUX SR RR UR
Rated heating capacity (kW) 1.10 1.80 2.60 3.50
Nozzle diameter (1/100 mm) 100 126 160 190
Reduced flow rate (W) 400 500 750 1600
Primary air (mm) 1 1 1 1.5
5 LPG G30/31 - 30/37 mbar AUX SR RR UR
Rated heating capacity (kW) 1.10 1.8 2.6 3.5
Nozzle diameter (1/100 mm) 48 62 76 87
Reduced flow rate (W) 400 500 750 1600
Primary air (mm) 1.5 1.5 1.5 2
Rated flow rate G30 (g/h) 80 131 189 254
Rated flow rate G31 (g/h) 79 129 186 250
Loading ...